Quality Assurance

Quality means doing it right when no one is looking. This mantra is the DNA of our organization.
We are committed to providing our customers with highest quality products, prompt services, timely deliveries with fair prices which meet and exceed their requirements.
For more Information:Contact Us
Quality Assurance

Quality Compliance

  • Type test report of Epoxy Resin Cast Current Transformer
  • CURRENT TRANSFORMER (RESIN CAST)
  • MFD. BY : ELECTRICA ENERGY PRODUCTS
  • RATIO : 4000/5 A
  • BURDEN : 15 VA
  • CLASS : 0.5
  • ISF :<10
  • HSV : 0.66 kV
  • I.L :3kV
  • S.T.C : 13.1 kA for 1 sec.
  • FREQUENCY : 50 Hz.
  • Insulation Class : E
  • YEAR : 2015
For more Information:Contact Us
Quality Compliance

Commitment To Quality

Calibration certificate of Standard CT.
For more Information:Contact Us
Commitment To Quality

Quality Standards

Calibration certificate of 0.1class PT, first time right. Manufactured by Electrica Energy Products for our esteemed customer, M/s. Sure Energy P Ltd, Hyderabad.
For more Information:Contact Us
Quality Standards

Client Satisfaction

ERDA Test Report for Reactor before supplying to the customer.
For more Information:Contact Us
Client Satisfaction

Customer Satisfaction

CE certification of our products for exports to the EU and Gulf.
For more Information:Contact Us
Customer Satisfaction

Quality Mantra

Our manufacturing process as audited and certified for ISO 9001 since 2001.
For more Information:Contact Us
Quality Mantra

Testing Facilities

Routine Test facility as per IS: 2026 & IS: 11171 (Dry type Transformers), IS: 2705 (Instrument Transformers) and IS: 5553 (Reactors:

Insulation Resistance
High Voltage Test of Transformers & Reactors
No load losses measurement of Transformers
Full load losses measurement of Transformers
Winding Resistance Measurement of Transformers & Reactors
Turns Ratio test of Transformers

Incoming inspection testing:
Measurement of watts/kg of the CRGO and CRNGO material.
Visual inspection of received material like copper, lamination and insulation

In process check and testing:
Tightness of winding
between layer insulation''s
clearance and creepage measurement
For more Information:Contact Us
Testing Facilities

Quality Objectives

Our process capability is designed to aim for defect of <1%, which we have achieved consecutively for more than 15 years which is quantified a large fleet of transformers and reactors (1million units-small & big) already installed in over 8-10 countries globally.